Plumbers NZ is New Zealand's largest online plumbing, gas and drainage resource. Plumbing exam help, plumbing news, directory and free quotes.

Author Topic: Running hot and cold water pipes underground between buildings  (Read 5373 times)

0 Members and 1 Guest are viewing this topic.

Offline roberto

  • Full Member
  • ***
  • Posts: 168
  • Karma: +4/-0
hi,

I am going to do my sister in-laws plumbing on her new ensuite, i need to run a hot and cold feed from in the wall in the original bathroom under the ground and over to where the new ensuit is, the house is shaped in a "U" shape where the existing bathroom and new ensuite will be.

Is there anything special I should do in regards to the hot line under ground with depths, lagging, size of pipe etc, I will be piping out the ensuite in dux, as far as im aware you cant install dux pipe underground?

The distace would only be 3 meters between the two rooms and its just a garden area with a few ferns and shrubs growing, there wil be no foot traffic at all.


Thanks

Linkback: https://www.plumbers.nz/ask-plumbers-trade/43/running-hot-and-cold-water-pipes-underground-between-buildings/1067/

Offline danieltkd

  • Jr. Member
  • **
  • Posts: 8
  • Karma: +1/-0
Re: Running hot and cold water pipes underground between buildings
« Reply #1 on: April 14, 2012, 09:58:09 PM »
You will be alright.sounds like you are already thinking about the right things.
   -- Metal in ground---- protect.
   -- Flow  ---- if someone turn on a tap somewhere else in the house,will it affect the shower. Pipe size.
 The reg.s on depth keep changing.

Offline roberto

  • Full Member
  • ***
  • Posts: 168
  • Karma: +4/-0
Re: Running hot and cold water pipes underground between buildings
« Reply #2 on: April 19, 2012, 04:53:25 PM »
thanks,

I have alredy completed the job, the distance underground was only 1.8m and i used lagging and fed both pipes through a pvc wastepipe, around 300 deep,


cheers

Offline Thunderhead

  • Sr. Member
  • ****
  • Posts: 341
  • Karma: +37/-3
Re: Running hot and cold water pipes underground between buildings
« Reply #3 on: April 19, 2012, 05:33:51 PM »
pretty much sounds like what we do when were running underslab pipe work for an island bay kitchen....lagg the pipe for heat loss and protection and back fill with fines or best sand and where the pipe passes through the slab we put a 50mm pvc collar arount the pipe for further protection.


Share via digg Share via facebook Share via linkedin Share via twitter

Similar Topics

  Subject / Started by Replies / Views Last post
xx
Wetback problem pipes hot when fire is cold

Started by Gus Wallis

4 Replies
3993 Views
Last post June 21, 2013, 09:09:46 PM
by Gus Wallis
xx
Low cold water pressure

Started by Richo

1 Replies
3649 Views
Last post April 27, 2011, 06:53:11 PM
by Thunderhead
xx
Cold Water Expansion Valve

Started by woody

1 Replies
3650 Views
Last post September 11, 2011, 12:37:14 PM
by Thunderhead
xx
Hot water cylinder hot and gets cold quick

Started by boots_nz

6 Replies
12469 Views
Last post June 04, 2013, 10:39:15 PM
by Plumber
 
Share this topic...
In a forum
(BBCode)
In a site/blog
(HTML)