Plumbers NZ is New Zealand's largest online plumbing, gas and drainage resource. Plumbing exam help, plumbing news, directory and free quotes.

Author Topic: How Not To Flash a hot water vent pipe  (Read 3602 times)

0 Members and 1 Guest are viewing this topic.

Offline Fordy

  • Jr. Member
  • **
  • Posts: 40
  • Karma: +4/-0
How Not To Flash a hot water vent pipe
« on: August 03, 2016, 08:49:01 AM »
The picture says it all - this installer had shares in the silicone manufacturing plant.

Linkback: https://www.plumbers.nz/dodgy-plumbing-or-great-plumbing/4/how-not-to-flash-a-hot-water-vent-pipe/2022/

Offline integrated

  • Sr. Member
  • ****
  • Posts: 412
  • Karma: +37/-2
Re: How Not To Flash a hot water vent pipe
« Reply #1 on: August 03, 2016, 07:14:27 PM »
obviously a temporary overnight job the roofers did when replacing the roof - clearly you can see there was an over flashing/soaker and a dektite on top of that

Offline Fordy

  • Jr. Member
  • **
  • Posts: 40
  • Karma: +4/-0
Re: How Not To Flash a hot water vent pipe
« Reply #2 on: August 03, 2016, 09:27:22 PM »
nope... you can see half a bracket cut down to cover the hole, then silicone it all together, it was actually leaking, as was the dektite and soaker (you can see the rust)
it was a handyman who reroofed this one charged 13k for his efforts we were then hired  to redo the bulk of the flashings and tidy up - I loathe fixing FU's  :)

Added some more pictures so you get the general idea

Offline integrated

  • Sr. Member
  • ****
  • Posts: 412
  • Karma: +37/-2
Re: How Not To Flash a hot water vent pipe
« Reply #3 on: August 03, 2016, 10:45:02 PM »
yeah ok - thats pretty bad


those soakers are terrible - not sure what they were thinking with those, due to no actual ridge line they would have to extend to the other side if not all the way down to the bottom of tray - not just the soakers that are terrible but, the parapets as well and sawtooth much?

Offline Fordy

  • Jr. Member
  • **
  • Posts: 40
  • Karma: +4/-0
Re: How Not To Flash a hot water vent pipe
« Reply #4 on: August 04, 2016, 12:11:45 PM »
yeh we redid all the soaker flashings, ripped the parapet flashings off and put a timber packer all the way around on the inside as they were made too wide and were rattling in the breeze. Put in a new chimney as the old one was had it and leaking inside.




Share via digg Share via facebook Share via linkedin Share via twitter

Similar Topics

  Subject / Started by Replies / Views Last post
xx
bathroom waste water pipe alterations

Started by Glycerine

1 Replies
3341 Views
Last post September 29, 2011, 06:15:41 PM
by Thunderhead
xx
head pipe size? hot water pressure!!

Started by myles

7 Replies
5777 Views
Last post April 12, 2014, 10:56:28 PM
by myles
xx
Constant dripping in overflow pipe on Hot Water Cylinder

Started by Wigglywormnz

3 Replies
21085 Views
Last post February 28, 2011, 08:43:50 PM
by Plumber
xx
Replacing galvanized pipe main supply and water pressure

Started by toycollector10

21 Replies
14380 Views
Last post April 13, 2013, 07:39:06 AM
by Rodza1
 
Share this topic...