drainlayers piping under slab
« on: July 14, 2011, 10:07:46 PM »
Been talking to local inspector , they stopped a drainlayer putting in drainage under a floor , said plumbers only are permitted to lay drainage inside building envelope , drainlayer said thats not correct it still drainage and I am able to do it .
Inspector checked with the board and were sent definition of drainage , it does not say anything about underslab requiring plumbers only ,
I know there was a determination by Routhan to clear up the situation and to be honest I thought it was a good outcome  , it seems he may not have had the authority to stop drainlayers putting in underfloor drainage , or for that matter elevated drainage if it is drainage principals , will post again when I hear more .
Anybody heard about this or had any issues

Linkback: https://www.plumbers.nz/drainage/83/drainlayers-piping-under-slab/752/

Offline wombles

  • Full Member
  • ***
  • Posts: 203
  • Karma: +13/-0
Re: drainlayers piping under slab
« Reply #1 on: July 15, 2011, 12:05:12 PM »
SOme time ago (2 - 3 years) in one of the "Board News" issues there was a definition of drainlaying being any work outside the apron of the house and plumbing being anything within. This of course is different to what the act says on their website

Offline peasea

  • Jr. Member
  • **
  • Posts: 99
  • Karma: +15/-1
Re: drainlayers piping under slab
« Reply #2 on: July 18, 2011, 05:15:04 PM »
 Hi here is the reply from Kern Uren , I guess what he says is legal ?


-----Original Message-----
From: Kern Uren [mailto:Kernuren@pgdb.co.nz]
Sent: Friday, 15 July 2011 3:27 p.m.
To: Cc: licensing
Subject: RE: Determination of drainlaying


Hello
 

Simply put, drainlaying is in the ground and remains outside of the building envelope (below the base coarse).  Please note that the unit standards and indeed the National Certificate that Drainlayers are trained in do not make provision for them to undertake in slab work such as that contained in AS/NZS 3500:2.

 

Happy to discuss this with you.

 

Kind regards,

 

 

Kern U’ren

Deputy Registrar

Plumbers, Gasfitters and Drainlayers Board

p: 04 495 2614   f: 04 494 2975   m: 027 494 2976 w: www.pgdb.co.nz




PRIVILEGED AND CONFIDENTIAL

 

This email contains CONFIDENTIAL INFORMATION


Share via digg Share via facebook Share via linkedin Share via twitter

Similar Topics

  Subject / Started by Replies / Views Last post
xx
WC drainage through slab

Started by robbie.peacocke

1 Replies
2333 Views
Last post May 11, 2017, 11:49:30 AM
by robbie.peacocke
xx
Polybutylene Piping

Started by regan41

10 Replies
8642 Views
Last post April 15, 2014, 09:37:25 PM
by Jaxcat
question
Proprietary piping systems

Started by justinventions

0 Replies
2030 Views
Last post November 09, 2009, 10:05:01 AM
by justinventions
xx
The Plumbers, Gasfitters and Drainlayers Act 2006

Started by Plumber

7 Replies
9874 Views
Last post June 29, 2010, 10:03:16 PM
by TS
 
Share this topic...
In a forum
(BBCode)
In a site/blog
(HTML)