Question 8
« on: April 20, 2009, 02:14:34 PM »
QUESTION 8
(a)  When a drain passes through a below-ground external wall, it must comply with certain criteria.
  Using your knowledge of AS/NZS 3500 Part 2: Sanitary plumbing and drainage, answer the
following questions.
 (i)   State what two fittings must be fitted to the drain within 800mm of the external face of
the wall, and state the distance apart they must be.
  Fittings:
  Distance:
(2 marks)

 (ii)  State the requirement that must be met between the drain and the penetration 
of the wall.
(1 mark)

(b)   During the course of any work, extraneous matter must be prevented from entering a sewer.
List THREE different types of extraneous matter.
 1
 2
 3
(3 marks)

(c)   AS/NZS 3500 Part 2: Sanitary plumbing and drainage states that concrete pads used to
support drains must be a minimum of 100mm thick.
 Based on your knowledge of this standard, answer the following.
 (i)   State THREE situations, apart from unstable ground, where concrete pads used to
support drains must be laid.
  1
 
  2
  3
(3 marks)
 (ii)   Concrete pads supporting drainage must be laid no closer than 20mm to a joint. 
State the type of joint.
 
 
(1 mark)
Total 10 marks

Linkback: https://www.plumbers.nz/drainlaying-exam-november-2008/26/question-8/209/

Offline mrchop

  • Jr. Member
  • **
  • Posts: 14
  • Karma: +0/-0
Re: Question 8
« Reply #1 on: May 22, 2010, 05:35:52 PM »
a)  When a drain passes through a below-ground external wall, it must comply with certain criteria.
  Using your knowledge of AS/NZS 3500 Part 2: Sanitary plumbing and drainage, answer the
following questions.
 (i)   State what two fittings must be fitted to the drain within 800mm of the external face of
the wall, and state the distance apart they must be.
  Fittings: must be of the flexiable kind ie: rubber ring, sleeve jointed
  Distance: no more the 600mm
(2 marks)

 (ii)  State the requirement that must be met between the drain and the penetration 
of the wall.
(1 mark) must be a water tight conection so no ground water can penetrate the conection

(b)   During the course of any work, extraneous matter must be prevented from entering a sewer.
List THREE different types of extraneous matter.
 1 rock ,stone
 2 sand or bedding matter
 3 and surface or ground water
fixing christchurch city one pipe at a time.


Share via digg Share via facebook Share via linkedin Share via twitter

Similar Topics

  Subject / Started by Replies / Views Last post
xx
Question 15

Started by LisaS

0 Replies
2212 Views
Last post February 11, 2009, 08:59:20 AM
by LisaS
xx
Question 14

Started by LisaS

0 Replies
1876 Views
Last post February 11, 2009, 08:59:42 AM
by LisaS
xx
Question 13

Started by LisaS

0 Replies
1938 Views
Last post February 11, 2009, 09:00:14 AM
by LisaS
xx
Question 12

Started by LisaS

0 Replies
2002 Views
Last post February 11, 2009, 09:01:09 AM
by LisaS
 
Share this topic...
In a forum
(BBCode)
In a site/blog
(HTML)