help with a exam Question
« on: March 31, 2010, 10:47:30 PM »
Hey guys, sitting my rego in june , just came across a question I cant work out.

Give four reasons why gas pressure in an installation may be insufficient at times of high consumption?


I have come up with two answers I think are correct, need two more

1. pipe size to small
2. low supply pressure


thanks

Linkback: https://www.plumbers.nz/plumbing-gas-fitting-and-drainlaying-apprentice-support/3/-help-with-a-exam-question/386/

Offline hefzibah

  • Jr. Member
  • **
  • Posts: 19
  • Karma: +1/-0
Re: help with a exam Question
« Reply #1 on: April 01, 2010, 10:01:51 PM »
When doing any exam, make sure you put down an answer, even if you are unsure. but first write the answer that you do know followed by the answers you are unsure of, markers will mark first 4 , 6 ,7  etc answers.Answering your question write down anything that will affect an installation, incorrect size of GMS is another answer.. hit the books and good luck..

Offline crusty

  • Jr. Member
  • **
  • Posts: 10
  • Karma: +0/-0
Re: help with a exam Question
« Reply #2 on: April 05, 2010, 10:18:33 AM »
The filter in the meter regulator could be packed with dust.

Offline crusty

  • Jr. Member
  • **
  • Posts: 10
  • Karma: +0/-0
Re: help with a exam Question
« Reply #3 on: April 12, 2010, 10:43:36 AM »
Another thoght just came to mind!  The orifice in the regulator is possibly too small to carry the volume required on high demand.

Offline crusty

  • Jr. Member
  • **
  • Posts: 10
  • Karma: +0/-0
Re: help with a exam Question
« Reply #4 on: April 12, 2010, 01:21:03 PM »
Another thought just came to mind!  The orifice in the regulator is possibly too small to carry the volume required on high demand.


I must be loosing my marbles! A couple of other things that cause regulators to act up pressure wise are: May have a broken or fatigued pressue spring.  And also a blocked breather hole which will prevent the diaphragm from moving either up or down, so the pressure will be high or low depending on the inlet pressure.

Offline yzhardy

  • Jr. Member
  • **
  • Posts: 13
  • Karma: +2/-0
Re: help with a exam Question
« Reply #5 on: May 16, 2010, 12:36:42 PM »
I would put it this way:

1. Inadequate pipe sizing.
2. Incorrect sizing of GMS or first stage regulator
3. LP Gas unable to evaporate sufficiently from the bottles.
4. (Possibily) Blocked line filter.....


Share via digg Share via facebook Share via linkedin Share via twitter

Similar Topics

  Subject / Started by Replies / Views Last post
xx
Past Exam Paper question

Started by Jayp

2 Replies
10292 Views
Last post June 11, 2012, 08:32:38 AM
by Plumber
xx
help with question from past certifying exam

Started by billyhealey1993

0 Replies
2208 Views
Last post April 21, 2020, 03:46:00 PM
by billyhealey1993
xx
Gasfitting Crasftman Exam Question..need clarification

Started by Plumbher

8 Replies
3859 Views
Last post May 02, 2010, 04:04:19 PM
by tapman
xx
Question 15

Started by LisaS

0 Replies
2212 Views
Last post February 11, 2009, 08:59:20 AM
by LisaS
 
Share this topic...
In a forum
(BBCode)
In a site/blog
(HTML)