Hi guys, Just a quick question I come across the other day, its from the certifying plumber exam from November 2011, question one of the multiple choice section

1. What is the maximum diameter for a roof penetration that is permitted to be sealed with an EDPM rubber boot flashing before a soaker flashing is required??

The possible answers are as follows...

A. 50mm
B. 60mm
C. 75mm
D. 90mm
E. 110mm

I had just been reading E2 External Moisture  which covers pipe penetrations and flashings. My copy of E2 also includes all the latest amendments. It says that  EDPM rubber boot flashings are"Suitable for pipes UP TO 85mm diameter'' (page 87)  before a soaker flashing is required so I answered C. 75mm as 90mm is techically wrong as it is 5mm to big to use a EDPM rubber boot.

To my amazement I was wrong and the answer was B. 60mm...Can anyone assist me is seeing where I went wrong and what standard or code I should have referenced or is the model answer wrong? Is it in AS/NZS 3500 somewhere and I missed it??

Comments would be appreciated. Questions are hard enough as it is some of them, I need to know what I am learning is correct.

Cheers


Linkback: https://www.plumbers.nz/plumbing-gas-fitting-and-drainlaying-apprentice-support/3/certifying-plumber-question-nov-2011-regarding-edpm-rubber-boot-flashings/1128/
The Plumbers Gasfitters And Drainlayers Board- "White Collar Mafia"

Offline Enn

  • Full Member
  • ***
  • Posts: 192
  • Karma: +22/-1
  • Ex-chef
I remember hearing about  this  around a year ago

''any roof penetration greater than 60mm will have to be trayed up to the ridge"

i thought it was a T.A  requirement ,  however it must be in a code somewhere in external moisture/ penetrations .....



 

''Never have so many been fooled by so few''
Plumbing is not a career it is a disease....

Offline o2b007

  • Jr. Member
  • **
  • Posts: 77
  • Karma: +6/-0
  • time for change!!
E2 page 80 8.4.17
Roof penetrations shall be flashed as follows:
a) Pipe penetrations up to 60 mm shall be
flashed using an EPDM boot flashing as
shown in Figure 53,
b) Pipe penetrations up to 500 mm shall be
flashed using a soaker flashing and EPDM
boot flashing as shown in Figure 54,

Offline Rodza1

  • Sr. Member
  • ****
  • Posts: 281
  • Karma: +20/-2
I just had another look, I see what has happened now. It has been amended in Aug 2011 to 85mm from 60mm so the older exam I did the question had the right answer at the time but now it seems to have changed. I printed my copy of E2 about 3weeks ago so it has all the latest amendments which are written next to the affected paragragh. In my version the same 8.4.17 is page 86 (Amend 5 Aug 2011). Thanks for taking the time to look it up man, makes sense now ive found the amendment reference.
Learn something new every day  ;D

Offline robbo

  • Hero Member
  • *****
  • Posts: 1259
  • Karma: +83/-7
Rodza, it`s a sad day when you do not learn something new,cheers

Offline Rodza1

  • Sr. Member
  • ****
  • Posts: 281
  • Karma: +20/-2
I reckon, its what keeps me going. And sane

Offline Wendi R

  • Jr. Member
  • **
  • Posts: 10
  • Karma: +0/-0
  • Im new @ Plumbers NZ!
Re: Certifying Plumber Question Nov 2011 Regarding EDPM Rubber Boot Flashings
« Reply #6 on: December 10, 2014, 07:41:38 PM »
I don't know the answer and I feel the question is quiet tough. I never seen such type of questions asked in any of the plumbing exams.


Share via digg Share via facebook Share via linkedin Share via twitter

Similar Topics

  Subject / Started by Replies / Views Last post
clip
CERTIFYING PLUMBER EXAM QUESTIONS & ANSWERS 2011

Started by Plumbers Helper

0 Replies
1612 Views
Last post April 16, 2013, 10:24:54 AM
by Plumbers Helper
xx
$511.11 to get licensed as a certifying plumber!

Started by spud

23 Replies
13371 Views
Last post September 30, 2011, 09:50:31 AM
by Badger
xx
9195 Certifying Plumber Exam Nov 2010

Started by woody

38 Replies
16000 Views
Last post February 20, 2011, 11:47:41 PM
by Jaxcat
xx
CERTIFYING PLUMBER EXAM QUESTIONS & ANSWERS 2010

Started by Plumbers Helper

0 Replies
2494 Views
Last post September 14, 2011, 04:42:10 PM
by Plumbers Helper
 
Share this topic...
In a forum
(BBCode)
In a site/blog
(HTML)