Author Topic: HWC vs. instantaneous water heaters?  (Read 3974 times)

0 Members and 1 Guest are viewing this topic.

Offline molumania

  • Jr. Member
  • **
  • Posts: 4
  • Karma: +0/-0
HWC vs. instantaneous water heaters?
« on: October 13, 2008, 12:12:58 AM »
I made an experiment to reduce my power bill and started to switch off the Hot Water Cylinder after showers and turned it back on 3-4 hours before the next shower and successfully went down from 14 kw/h to 6-7 kw/h per day including all other home appliances.
I want to go a step further now: I am planning now to register with Genesis for a night plan and leave the HWC only at night turned on but switched off during the day. The offer very low night rates.

If this was my own home then I would definitely go for instantaneous water heaters. I cannot understand why so many people use Cylinders.

What are the benefits? ??? Why did it become so popular although it takes so much room, costs more power and runs out when 2 need to shower (135L)?

Linkback: https://www.plumbers.nz/q-and-a-hot-water-cylinders/44/hwc-vs-instantaneous-water-heaters/43/

Offline Crankin

  • Newbie
  • *
  • Posts: 3
  • Karma: +1/-0
Re: HWC vs. instantaneous water heaters?
« Reply #1 on: October 29, 2008, 09:49:48 PM »
my personal experience of instataneous water heaters is crap, they do have there uses but i think a cylinder is far better.  Because you are storing an amount of water when the power goes off you still have volume of water to use, now i know infinty's can come with battery back up but that isn't included when you purchase the item off the shelf it is an EXTRA cost.  Dont get me wrong infinitys are good but they have there place, like if i had a holiday home i would have one cause i could arrive and a flick of a switch you have hot water.  If it comes down to running out of hot water then you could time showers, install a tempering valve, addjust tempering valve, turn up temperature on thermostat.  Because you are turning your hwc off the cylinder has to use power to heat the volume of water to set temp on thermostat this requires power usage, thermostats should be set at temp around 55-60 thermostat has a 7 degree + - heating range, your cylinder should heat water to 60 degrees once in a 24 hour period this is to kill bacteria.  If that doesn't solve your problem then maybe the cylinder is too small for the amount of occupants in the house a possible upgrade might be the case.  Oh and the power board switches your cylinder off for you through the ripple rely at the main feed into property this is to save on power and prevent grid over loading.


Share via digg Share via facebook Share via linkedin Share via twitter

Similar Topics

  Subject / Started by Replies / Views Last post
clip
Flue clearance on instant water heaters

Started by Plumber

4 Replies
7909 Views
Last post December 12, 2015, 02:50:01 PM
by aboutgas
xx
Looking for an instantaneous Gas Hot Water system

Started by jrgasandwater

2 Replies
2113 Views
Last post December 05, 2018, 05:43:48 PM
by jrgasandwater
xx
clearances from a external instantaneous water heater

Started by bowtieboy

75 Replies
40944 Views
Last post June 21, 2020, 03:28:04 PM
by Macmole
xx
Sakura SH-550A Instantaneous water heater

Started by Chris Downey

2 Replies
4144 Views
Last post March 18, 2017, 08:33:23 PM
by Jaxcat
 
Share this topic...
In a forum
(BBCode)
In a site/blog
(HTML)