Author Topic: Low hot water pressure - wetback system  (Read 20112 times)

0 Members and 1 Guest are viewing this topic.

Offline THOMAS90

  • Newbie
  • *
  • Posts: 3
  • Karma: +0/-0
Low hot water pressure - wetback system
« on: September 23, 2011, 07:56:27 AM »
Hi Plumbers,
I have a low pressure hot water cylinder with wetback but my hot water pressure is lousy.
Can anyone provide me with good advice on how best to fix this.
I want to retain the wetback - it's only a couple of years young!
What are options - a booster pump?
The open vent pipe is already reaching the sky & the water shoots out the exhaust when the fires cranking.
The ajax is already wound up as high as it will go before spilling.
A plumber installed parallel ajax valves but this hasn't improved anything.
Any suggestions?
I need a good plumber - I'm in Napier Hawkes Bay.
Look forward to hearing from you.

Craig

Linkback: https://www.plumbers.nz/q-and-a-water-pressure/50/low-hot-water-pressure-wetback-system/848/

Offline integrated

  • Sr. Member
  • ****
  • Posts: 412
  • Karma: +37/-2
Re: Low hot water pressure - wetback system
« Reply #1 on: September 23, 2011, 07:41:49 PM »
Hi Plumbers,
I have a low pressure hot water cylinder with wetback but my hot water pressure is lousy.
Can anyone provide me with good advice on how best to fix this.
I want to retain the wetback - it's only a couple of years young!
What are options - a booster pump?
The open vent pipe is already reaching the sky & the water shoots out the exhaust when the fires cranking.
The ajax is already wound up as high as it will go before spilling.
A plumber installed parallel ajax valves but this hasn't improved anything.
Any suggestions?
I need a good plumber - I'm in Napier Hawkes Bay.
Look forward to hearing from you.

Craig


Hi craig, parallel ajax valves wont do anything for pressure - it allows increased flow in times of simultaneous/multiple hot water draw-off from fixtures

you have three options - you mentioned two

1/ increase exhaust height, go to a 7.6m prv = cheapest option
2/ install hot water booster pump - this should be installed AFTER tempering valve = mid point cost wise
3/ change to mains pressure HWC with wet back coil = most expensive option

cheers

Offline THOMAS90

  • Newbie
  • *
  • Posts: 3
  • Karma: +0/-0
Re: Low hot water pressure - wetback system
« Reply #2 on: September 26, 2011, 06:13:07 PM »
Hi,
Thanks for the feedback.
The wetback & cylinder exhaust are pretty tall already but certainly not 7.6m - is this measured from the top of the cylinder or from the ajax valve? I'm guessing the ajax since this is the point of pressure reduction.
If I increase the size of the pipe from from the tempering valve through to the shower from 15mm-20mm, I'm guessing I'll get more flow, but no increase in pressure - so probably no benefit? What's the pros call on this?
Thanks,

Craig

Offline spud

  • Full Member
  • ***
  • Posts: 111
  • Karma: +13/-10
Re: Low hot water pressure - wetback system
« Reply #3 on: September 26, 2011, 06:56:57 PM »
Get rid of your tempering valve.

Offline roberto

  • Full Member
  • ***
  • Posts: 168
  • Karma: +4/-0
Re: Low hot water pressure - wetback system
« Reply #4 on: September 26, 2011, 09:26:17 PM »
be wary of removing your tempering valve, if anyone gets burnt by the hot water temp you could be responsible for their injuries,

Here in chch, if we are the last plumber/tradesman to work on a hot water cylinder with a wetback, (even if its just to replace a pressure reducing valve washer) and we notice there is no tempering valve, and do nothing about it, and someone gets burnt/injured - we are 100% responsible for not installing one - as it is a safety device and could face prosecution.

Offline robbo

  • Hero Member
  • *****
  • Posts: 1259
  • Karma: +83/-7
Re: Low hot water pressure - wetback system
« Reply #5 on: September 26, 2011, 10:08:27 PM »
hi guys/roberto, i don`t believe that is true where is that written? can you produce the reg or paper that states what you are saying,cheers

Offline spud

  • Full Member
  • ***
  • Posts: 111
  • Karma: +13/-10
Re: Low hot water pressure - wetback system
« Reply #6 on: September 26, 2011, 10:31:29 PM »
That is total crap

Offline spud

  • Full Member
  • ***
  • Posts: 111
  • Karma: +13/-10
Re: Low hot water pressure - wetback system
« Reply #7 on: September 26, 2011, 10:35:32 PM »
Hi I'm here to put a washer on your orb but I've noticed you don't have a tempering valve. I'm going to have to put one in and it's going to cost you $400.

But I don't have $400

I'm sorry but I legally have to install one. Go get your cheque book.

Get out of my house

I'm sorry but I'm installing a tempering valve.

I don't want one get out.

I'm putting one in get out of my way

I'm calling the police

Offline spud

  • Full Member
  • ***
  • Posts: 111
  • Karma: +13/-10
Re: Low hot water pressure - wetback system
« Reply #8 on: September 26, 2011, 10:37:21 PM »
That's meant to be prv not orb. You get the picture

Offline Plumber

  • Administrator
  • Hero Member
  • *****
  • Posts: 736
  • Karma: +52/-2
  • ***#1 Plumber***
Re: Low hot water pressure - wetback system
« Reply #9 on: September 26, 2011, 11:17:03 PM »
Have you actually ever put a gauge on the shower to see what pressure you physically have?
Please note that the advice I am giving is only my opinion and not necessarily a fact.  Please refer to our terms and conditions.

Offline robbo

  • Hero Member
  • *****
  • Posts: 1259
  • Karma: +83/-7
Re: Low hot water pressure - wetback system
« Reply #10 on: September 27, 2011, 07:57:34 AM »
hi guys, this is the only info that i have on Temp valves don`t know if regs have changed but perhaps others could post updated if available,cheers

When are tempering valves needed:
* When a new solid fuel heater with a wet back is fitted.
* A new (not replacement) wet back fitted to an existing solid fuel heater.
* When an additional personal hygiene fixture is installed (i.e. shower unit). In this instance it is only
the new fixture that needs to be tempered but it is easier to temper all the fixtures.
* An owner wants to change the use of an existing building from private dwelling to early childcare
or retirement home.
* Any new hot water cylinders that supply personal hygiene fixtures or appliances (not direct
replacements).
* Bathroom alterations where personal hygiene fixtures are being shifted to new positions.
Please check with your local City Council / Building Authority for final confirmation.

Offline TNS

  • Newbie
  • *
  • Posts: 2
  • Karma: +0/-0
Re: Low hot water pressure - wetback system
« Reply #11 on: September 27, 2011, 08:46:55 AM »
It is a bit silly to suggest removing a safety device and performing an illegal practice, so don't remove the TLV.

HWC's usually have a pressure rating, so the height of the exhaust should be from the base of the HWC.

You cant increase the hot water pressure more than the HWC pressure rating.

A TLV installed at the lowest point as possible increases the performance of the valve i.e. the lower it is installed, the more pressure there is to force water though it.

There are a few different shower roses/hoses that perform better under low pressure than others, shop around.

If any of this helps, good luck,,,, it its crap, let me know.

Offline spud

  • Full Member
  • ***
  • Posts: 111
  • Karma: +13/-10
Re: Low hot water pressure - wetback system
« Reply #12 on: September 27, 2011, 12:18:49 PM »
Are you guys actually taking this seriously? Dam! It's actually impossible to give good advice in a forum like this. There could be any one of a hundred factors leading to bad water pressure in this instance. It's illegal for home owner to tamper with any of this sanitary plumbing installation so why not just call a registered plumber to check it out? I think that any advice given on here is encouraging illegal plumbing.

Offline integrated

  • Sr. Member
  • ****
  • Posts: 412
  • Karma: +37/-2
Re: Low hot water pressure - wetback system
« Reply #13 on: September 27, 2011, 01:19:30 PM »
you're right about certain advice been illegal there A1

under health & safety act if you dont take all practicable steps to ensure safety of yourself and others you are held responsible

would it stand in court?  dont know - havent taken the risk to find out

as for where and when tlv's are req to be installed that is up to each individual T.A

imho it is good trade practice to install safety valving, E.Q straps etc on any installation if you are doing any sort of work at any particular property, im sure all would agree - 99% of the time when asked for quote etc for any work this is checked - the client/property owner is informed of dangers/hazards present and is quoted based on this

99% of clients are glad to be informed of this and much work is gained through this advice alone

as has been stated, if property has been plumbed correctly in the first place for low pressure hot water system with all valving set up properly there wont be an issue - the layman would not be able to tell it wasnt a "mains" pressure system...

Offline spud

  • Full Member
  • ***
  • Posts: 111
  • Karma: +13/-10
Re: Low hot water pressure - wetback system
« Reply #14 on: September 27, 2011, 01:51:32 PM »
It's only illegal if you actually do it mate. My comment about t l v was tongue in cheek because the forum is absurd. We shouldn't be encouraging people to do their own plumbing or giving any kind of advice on how to. Their was a good forum on here ..... The plumbers blacklist one. Where's that gone?


Share via digg Share via facebook Share via linkedin Share via twitter

Similar Topics

  Subject / Started by Replies / Views Last post
question
HJ Coopers Duplex S/Steel solar/wetback ready Mains Pressure HWC queries

Started by Rodza1

0 Replies
3051 Views
Last post September 23, 2012, 01:02:11 PM
by Rodza1
xx
hwc on wetback or gas hot water

Started by roberto

1 Replies
1800 Views
Last post July 01, 2013, 10:24:11 PM
by Plumber
xx
Wetback Hot Water Cylinder install!

Started by naturaljandal

2 Replies
2825 Views
Last post August 25, 2021, 02:11:59 PM
by Plumber
xx
Looking for an instantaneous Gas Hot Water system

Started by jrgasandwater

2 Replies
2165 Views
Last post December 05, 2018, 05:43:48 PM
by jrgasandwater
 
Share this topic...
In a forum
(BBCode)
In a site/blog
(HTML)